+--------------------------------------------------------------------------------------------------+ | COMPATIBILITY NOTES RELATED TO PHILIPS "HCS80" | +--------------------------------------------------------------------------------------------------+ ADDITIONAL NOTES ---------------- If the DIN 5-poles Socket is present on VIDEOTEX TERMINAL PHILIPS "HCS80", this ADF-258 WI-FI MODEM (PCB Version 1.00) can be used. Recap of the operations/commands to issue to the Terminal: 1) Set the correct protocol (Teletel 40 columns -it might be displayed as CEPT2. Do not use CEPT3) with the command: FUNZ+V T (press and hold down the "FUNZ" key, the press the "V" key. Release both keys, then press the "T" key) 2) Set the correct Baud Rate (4800) with the command: FUNZ+P 4 (press and hold down the "FUNZ" key, the press the "P" key. Release both keys, then press the "4" key)